Part Number Hot Search : 
CPC1986 R5F1016J DL472 E13005 MMBTA6 F3205Z G4PC50 ECCM5
Product Description
Full Text Search
 

To Download LTA065B0D0F Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ( 1 / 10 ) 2005 - 11 - 10 (ver.0.1r) product information features: (1)6.5 ? vga color display with high luminance (400cd/m 2 ) (2)wide viewing angle (vertical: 1 2 0 , horizontal: 1 4 0 ) (3)built in long life lamps (mttf:50,000 h) (condition; t a=25 c, i fl =6 .0ma(rms)(continuous lighting)) (4)replaceable structure of lamp units (5)rohs compliant mechanical specifications item specifications dimensional outline (typ.) 153.0( w ) x 118.0( h ) x 11.0max( d ) mm number of pixels 640( w ) x 480( h ) pixels active area 132.48( w ) x 99.36( h ) mm pixel pitch 0.207( w ) x 0.207( h ) weight (approximately) (250)g backlight twin ccfls, sidelight type absolute maximum ratings item min. max. unit ( v dd ) - 0.3 4.0 v supply voltage ( v fl ) 0 2.0 kv(rms) fl dr iving frequency ( f fl ) --- 100 khz input signal voltage ( v in ) - 0.3 v dd +0.3 v operating temperature * 1 - 10 70 c storage temperature - 20 80 c storage humidity (max. wet bulb temperature = 39 c) 10 90 %(rh) *1 : only operation is guarantied at operat ing temperature. display quality is evaluated at +25 c. electrical specification ( t a=25 c) ( recommended operation condition ) item min. typ. max. unit remarks ( v dd ) 3.0 3.3 3.6 v supply voltage ( v fl ) --- ( 33 0 ) --- v(rms) fl start voltage ( 1200 ) --- 1900 v(rms) t a= - 10 c high level input voltage ( v ih ) 0.7 v dd --- v dd low level input voltage ( v il ) 0 --- 0.3 v dd v * 1 ( i dd ) --- tbd --- ma current consumption * 2 ( i fl ) 3.0 6.0 6.5 ma(rms) power consumption * 2 * 3 --- tbd --- w i fl =6.0ma(rms) *2 : 8 color bars pattern *3 : except the efficiency of fl inverter optical specification ( t a=25 c) item min. typ. max. unit remarks contrast ratio ( cr ) 25 0 50 0 --- --- (upper+lower) --- 120 --- ?? viewing angle ( cr 3 10) (left+right) --- 140 --- ?? ( t on ) --- --- 50 ms response time ( t off ) --- --- 50 ms luminance (320) (400) --- cd/m 2 i fl =6.0ma(rms) lamp life time (mtbf) * 4 * 5 50,000 h *4 : conditions ; t a=25 c, i fl =6.0ma(rms), continuous lighting *5 : definitions of failure ; 1) lcd luminance becomes half of the minimum value. 2) lamp doesn ? t light normally. *the information contained herein is presented only as a guide for the applications of our products. no responsibility is assumed by tos hiba matsushita display technology or other rights of the third parties which may result from its use. no license is granted by implication or otherwise under any patent or patent rights of toshiba matsushita display technology or others. *the information contained herein may be changed without prior notice. it is therefore advisable to contact toshiba matsushita display technology before proceeding with the design of equipment incorporating this product. 17cm colour tft - lcd module (6.5 type) LTA065B0D0F (a - si tft) tentative toshiba matsushita display technology co., ltd all information is subject to change without notice. please read bottom notes. rohs compliant product www..net www..net
( 2 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F dimensional outline tentative unit : mm standard tolerance : ?} 0.5 1 0 5 . 5 8 2 - m 2 6 . 4 2 ( 5 8 . 6 ) 9 9 . 3 6 ( a c t i v e a r e a ) 1 0 . 5 8 . 9 2 5 9 + / - 0 . 3 2 9 . 5 + / - 0 . 3 3 . 1 + / - 0 . 3 1 1 8 . 0 ( 7 8 . 5 5 ) 6 0 + / - 1 0 c n 3 3 . 1 + / - 0 . 3 2 9 . 5 + / - 0 . 3 5 9 + / - 0 . 3 2 - m 2 1 2 . 6 1 1 3 8 . 3 4 9 . 2 5 1 3 2 . 4 8 ( a c t i v e a r e a ) 1 5 3 . 0 www..net www..net
( 3 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F unit : mm standard tolerance : ?} 0.5 3 1 . 6 8 . 9 9 . 1 5 7 . 6 4 - m 2 . 5 8 2 + / - 0 . 3 1 3 . 6 + / - 0 . 3 2 . 9 6 + / - 0 . 3 1 4 6 + / - 0 . 3 c n 1 c n 2 t b d a r e a www..net www..net
( 4 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F block diagram sequence of power supplies and signals www..net www..net
( 5 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F timing chart tv tvw vsync th hsync tv ?? p tvds tvde tvblnk de 479 480 1 2 th thw hsync thfp thds thde de 640 rgb data nclk 1 2 3 4 5 t v t vw vsync t vfp t h t vde t vds t vblnk hsyn c de 1 2 479 480 t h t hw t hde t hds t hfp 640 1 2 3 4 hsync de rgb data ncl t vde www..net www..net
( 6 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F timing specification 1) 2) 3) 4) 5) item symbol min. typ. max. unit 500 525 550 th frame period t v - 16.67 17.85 ms vertical blanking term t v blnk 20 45 70 th v - sync pulse width t vw 2 - - th vertical front por ch t v fp 2 - - th vertical data sync p eriod t vds 6 - - th vertical display term t vd e 480 480 480 th 740 800 860 tc horizontal period th 31.5 31.75 - us h - sync pulse width th w 8 160 - tc horizontal front porch thfp 8 - - tc horizontal data sync peri od thds 8 - - tc horizontal display term th d e 640 640 640 tc clock period tc 35.0 39.7 - n s clock ? h ? time tch 10.0 - - ns clock ? l ? time tcl 10.0 - - ns data setup time tds 5.0 - - ns data hold time tdh 10.0 - - ns item symbol min. typ. max. unit 500 525 550 th frame period t v - 16.67 17.85 ms vertical display term t vd e 480 480 480 th 740 800 860 tc one line scanning term th 31.5 31.75 - us horizontal display term th d e 640 640 640 tc clock period tc 35.0 39.7 - n s clock ? h ? time tch 10.0 - - ns clock ? l ? time tcl 10.0 - - ns data setup time tds 5.0 - - ns data hold time tdh 10.0 - - ns note 1) if nclk is fixed to "h" or "l" level for certain period while de is supplied, the panel may be damaged. note 2) please adju st lcd operating signal timing and fl driving frequency, to optimize the display quality. there is a possibility that flicker is observed by the interference of lcd operating signal timing and fl driving condition (especially driving frequency), even if th e condition satisfies above timing specifications and recommended operating conditions. note3 ) do not make tv , th and tvds fluctuate. note4) in case of using the long frame period, the deterioration of display quality, noise etc. may be occurred. note5 ) nclk count of each horizontal scanning time should be always the same. v - blanking period should be ? n ? x ? horizontal scanning time ? . ( n : integer) frame period should be always the same. www..net www..net
( 7 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F connector pin assignment for interface cn1 input signal connector : df19l - 30p - 1h / hirose electric co., ltd. mating connector : df19g - 30s - 1c terminal no. symbol function 1 gnd 2 nclk sampling clock 3 h - sync horizontal sync. 4 v - sync vertical sync. 5 gnd 6 r0 1) red display data (lsb) 7 r1 1) red display data 8 r2 1) red display data 9 r3 1) red display data 10 r4 1) red display data 11 r5 1) red display data (msb) 12 gnd 13 g0 1) green display data (lsb) 14 g1 1) green display data 15 g2 1) green display data 16 g3 1) green display data 17 g4 1) green display data 18 g5 1) green display data (msb) 19 gnd 20 b0 1) blue display data (lsb) 21 b1 1) blue display data 22 b2 1) blue display data 23 b3 1) blue display data 24 b4 1) blue d isplay data 25 b5 1) blue display data (msb) 26 de data enable 27 gnd 28 vdd +3.3v power supply 29 vdd +3.3v power supply 30 gnd note 1) see next page. cn2 input signal connector : df14h - 2p - 1.25h / hirose electric co., ltd. mating connecto r : df14 - 2s - 1.25c terminal no. symbol function 1 u d vertical reverse( ? l ? level or open ; normal, ? h ? level ; reverse) 2 r l horizontal reverse ( ? l ? level or open ; normal , ? h ? level ; reverse) cn3 ccfl power source connector : bhr - 04vs - 1 / japan solderless terminal mfg co., ltd. mating connector 3) : sm04(4.0)b - bhs - 1 / japan solderless terminal mfg co., ltd. terminal no. symbol function 1 v flh1 ccfl power supply ( high voltage) 2 v flh2 ccfl power supply ( high voltage) 3 n c 2) non connection (open) 4 v fll ccfl power supply (low voltage) note 2) nc terminal should be open. note 3) take away terminal no.3 of the mating connector. if does not take away, it may cause smoke burn of electrical parts by high voltag e. www..net www..net
( 8 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F 256k (k=1024) colors combination table display r5 r4 r3 r2 r1 r0 g5 g4 g3 g2 g1 g0 b5 b4 b3 b2 b1 b0 gray scale level black l l l l l l l l l l l l l l l l l l - blue l l l l l l l l l l l l h h h h h h - green l l l l l l h h h h h h l l l l l l - light blue l l l l l l h h h h h h h h h h h h - red h h h h h h l l l l l l l l l l l l - purple h h h h h h l l l l l l h h h h h h - yellow h h h h h h h h h h h h l l l l l l - basic color white h h h h h h h h h h h h h h h h h h - black l l l l l l l l l l l l l l l l l l l 0 l l l l l h l l l l l l l l l l l l l 1 l l l l h l l l l l l l l l l l l l l 2 : : : : : : l3 ? l60 h h h h l h l l l l l l l l l l l l l61 dark - light h h h h h l l l l l l l l l l l l l l62 gray scale of red red h h h h h h l l l l l l l l l l l l red l63 black l l l l l l l l l l l l l l l l l l l 0 l l l l l l l l l l l h l l l l l l l 1 l l l l l l l l l l h l l l l l l l l 2 : : : : : : l3 ? l60 l l l l l l h h h h l h l l l l l l l61 dark - light l l l l l l h h h h h l l l l l l l l62 gray scale of green green l l l l l l h h h h h h l l l l l l green l63 black l l l l l l l l l l l l l l l l l l l 0 l l l l l l l l l l l l l l l l l h l 1 l l l l l l l l l l l l l l l l h l l 2 : : : : : : l3 ? l60 l l l l l l l l l l l l h h h h l h l61 dark - light l l l l l l l l l l l l h h h h h l l62 gray scale of blue blu e l l l l l l l l l l l l h h h h h h blue l63 black l l l l l l l l l l l l l l l l l l l 0 l l l l l h l l l l l h l l l l l h l 1 l l l l h l l l l l h l l l l l h l l 2 : : : : : : l3 ? l 60 h h h h l h h h h h l h h h h h l h l61 dark - light h h h h h l h h h h h l h h h h h l l62 gray scale of white & black white h h h h h h h h h h h h h h h h h h white l63 www..net www..net
( 9 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F reliability test test conditions 1) the module should be driven and inspect ed under normal test conditions. 2) the module should not have condensation of water (moisture) on the module. 3) the module should be inspected after two or more hours storage in normal conditions (15 - 35 c,45 - 65%(rh)). 4) a module shall be used only for one test. specifications the module shall have no failure in the following reliability test items. test item test conditions result high temperature operation 1) 70 c 192 h ok high temperature storage 2) 8 0 c 192 h ok high temperature high humidity operation 1) 50 c 80% 192 h ok low temperature operation 1) - 10 c 192 h ok low temperature storage 2) - 20 c 192 h ok temperature shock 2) - 20 c ? 80 c 0.5h 0.5h 50 cycles ok mechanical vibration 2) 10 - 200 - 10hz sweep/cycle, 1.5 9.8m/s 2 constant, x.y.z each directions, 0.5h each ok mechanical shock 2) 50 9.8m/s 2 , 20ms, x, y, z direction, one time each ok note 1) operat ing note 2) non - operating definitions of failure for judgment shall be as follows: 1) function of the module should be maintained. 2) current consumption should be smaller than the specified value. 3) appearance an d display quality should not have distinguished degradation. 4) luminance should be larger than 50% of the minimum value specified in optical specification. www..net www..net
( 10 / 10 ) 2005 - 11 - 10 (ver.0.1r) LTA065B0D0F for safety lcd module is generally designed with precise part s to achieve light weighted thin mechanical dimensions. in using our modules, make certain that you fully understand and put into practice the warnings and safety precautions detailed in engineering information no.ee - n001,"cautions and instructions for tos hiba lcd modules". refer to individual specifications and technical data sheets (hereinafter called "td") for more detailed technical information. 1) special purposes a) toshiba matsushita display technology's standard lcd modules have not been customized f or operation in extreme environments or for use in applications where performance failures could be life - threatening or otherwise catastrophic. b) since toshiba matsushita display technology's standard lcd modules have not been designed for operation in e xtreme environments, they must never be used in devices that will be exposed to abnormally high levels of vibration or shock which exceed toshiba matsushita display technology's published specification limits. c) in addition, since toshiba matsushita disp lay technology standard lcd modules have not been designed for use in applications where performance failures could be life - threatening or catastrophic, they must never be installed in aircraft navigation control systems (such as, but not limited to traffi c collision avoidance system and air traffic indicator), in military defense or weapons systems, in critical industrial process - control systems (e.g., those involved in the production of nuclear energy), or in critical medical device or patient life - suppor t systems. 2) disassembling or modification do not disassemble or modify the module. it may damage sensitive parts inside lcd module, and may cause scratches or dust on the display. toshiba matsushita display technology doses not warrant the module, if custo mer disassembled or modified it. 3) breakage of lcd panel do not ingest liquid crystal material, do not inhale this material, and do not contact the material with skin, if lcd panel is broken and liquid crystal material spills out. if liquid crystal material comes into mouth or eyes, rinse mouth or eyes out with water immediately. if this material contact with skin or cloths, wash it off immediately with alcohol and rinse thoroughly with water. 4) glass of lcd panel be careful with chips of glass that may cause injuring fingers or skin, when the glass is broken. 5) electric shock disconnect power supply before handling lcd module. do not touch the parts inside lcd module and the fluorescent lamp's connector or cables in order to prevent electric shock, because hig h voltage is supplied to these parts from the inverter unit while power supply is turned on. 6) absolute maximum ratings and power protection circuit do not exceed the absolute maximum rating values under the worst probable conditions caused by the supply vo ltage variation, input voltage variation, variation in parts' constants, environmental temperature, etc., otherwise lcd module may be damaged. employ protection circuit for power supply, whenever the specification or td specifies it. suitable protection ci rcuit should be applied for each system design. 7) recommended operation conditions the performance and quality of the lcd panel are warranted only when the lcd panel is used within ? the recommended operation conditions ? . toshiba matsushita displ ay technology co., ltd. never warrants the performance and quality of the lcd panel when you use the lcd panel over ? the recommended operation conditions ? , although within ?the absolute maximum rating?. to use the lcd panel over ? the recommended operation conditions ? may have bad influence on the characteristics and reliability of the lcd panel and may shorten the life of the lcd panel . therefore, when designing the whole set, not to be over ? the recommended operation conditions ? , you should fully take care of supply voltage change , characteristic of connection parts, serge of input - and - output line, and surrounding temperature. 8) disposal when dispose lcd module, obey to the applicable environmental regulations. ! www..net www..net


▲Up To Search▲   

 
Price & Availability of LTA065B0D0F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X